Certificate of Analysis
HEMP QUALITY ASSURANCE TEST

Sample Name:

Yaas Biatch

Flower, Product Inhalable

Date Issued:

06/11/2024

Total THC 29.68%
Total CBD 0.091%
Sum Cannabinoids 35.77%
Total Cannabinoids 31.39%

Sample Information

Sample Details

Sample ID:240130T019

Batch Number:

Cultivator / Manufacturer

Show Details

Distributor / Tested For

Show Details

Share

Easily share a link to this results page with your friends, followers, or business partners.

Cannabinoid Analysis - Summary

Calculated using Dry-Weight

Total THC: 29.68%

Total CBD: 0.091%

Sum of Cannabinoids: 35.77%

Total Cannabinoids: 31.39%

Moisture:77.8%

Total THC/CBD is calculated using the following formulas to take into account the loss of a carboxyl group during the decarboxylation step:
Total THC = Δ9-THC + (THCa (0.877))
Total CBD = CBD + (CBDa (0.877))

Sum of Cannabinoids = Δ9-THC + THCa + CBD + CBDa + CBG + CBGa + THCV + THCVa + CBC + CBCa + CBDV + CBDVa + Δ8-THC + CBL + CBN

Total Cannabinoids = (Δ9-THC+0.877*THCa) + (CBD+0.877*CBDa) + (CBG+0.877*CBGa) + (THCV+0.877*THCVa) + (CBC+0.877*CBCa) + (CBDV+0.877*CBDVa) + Δ8-THC + CBL + CBN

Dry weight: The weight of a sample after it goes through the drying process.

Pursuant to section § 5724 of California Code of Regulations Title 16 Division 42. Department of Cannabis Control, the equation for moisture correction is:  Dry-weight percent cannabinoid = wet-weight percent cannabinoid / (1 − percent moisture / 100)

Sum of Cannabinoids: The concentration of each individual cannabinoid added together as they are, without accounting for decarboxylation. This measurement is of particular importance for certain cannabis products that are not intended to be heated prior to application or consumption.

Total Cannabinoids: The concentration of each acidic cannabinoid, multiplied by 0.877 to account for the loss of molecular mass that happens as it is converted to a neutral cannabinoid when heated. Then this calculated concentration is added to the concentrations of the corresponding neutral cannabinoid already present. This corrected data is of particular importance to both producers and consumers of products intended to be heated prior to application or consumption.

Safety Analysis - Summary

Pesticides: Pass

Heavy Metals: Pass

View Complete Test Results:

Tested by high-performance liquid chromatography with diode-array detection (HPLC-DAD). Calculated using Dry-Weight.

Method: QSP 1157 - Analysis of Cannabinoids by HPLC-DAD

Summary

Total THC: 29.68%

(Δ9-THC+0.877*THCa)

Total CBD: 0.091%

(CBD+0.877*CBDa)

Total Cannabinoids: 31.39%

Total CBG: 1.23%

Total CBG (CBG+0.877*CBGa)

Total THCV: 0.071%

Total THCV (THCV+0.877*THCVa)

Total CBC: 0.32%

Total CBC (CBC+0.877*CBCa)

Total CBDV: ND

Total CBDV (CBDV+0.877*CBDVa)

Learn more

The cannabis plant contains dozens of active compounds called cannabinoids. These compounds are the primary contributors to the psychoactive effects of cannabis.

Cannabinoid testing determines the potency of a sample to aid in dosage considerations.

Cannabinoid Test Results

02/02/2024

Result Views

Swipe left on table to see additional columns

Compound LOD/LOQ
(mg/g)
Measurement
Uncertainty
(mg/g)
Result
(mg/g)
Result
(%)
Tetrahydrocannabinolic Acid (THCa) 0.04 / 0.24 ±10.798 336.40 33.640
Cannabigerolic Acid (CBGa) 0.1 / 0.4 ±0.75 14.0 1.40
Cannabichromenic Acid (CBCa) 0.1 / 0.4 ±0.25 3.6 0.36
Δ9 Tetrahydrocannabinol (Δ9THC) 0.1 / 0.4 ±0.05 1.8 0.18
Cannabidiolic Acid (CBDa) 0.06 / 0.22 ±0.034 1.04 0.104
Tetrahydrocannabivarinic Acid (THCVa) 0.05 / 0.17 ±0.019 0.81 0.081
Cannabichromene (CBC) 0.1 / 0.2 N/A ND ND
Cannabidiol (CBD) 0.1 / 0.3 N/A ND ND
Cannabigerol (CBG) 0.2 / 0.5 N/A ND ND
Cannabicyclol (CBL) 0.1 / 0.4 N/A ND ND
Cannabinol (CBN) 0.07 / 0.20 N/A ND ND
Cannabidivarin (CBDV) 0.1 / 0.3 N/A ND ND
Tetrahydrocannabivarin (THCV) 0.07 / 0.21 N/A ND ND
Cannabidivarinic Acid (CBDVa) 0.02 / 0.22 N/A ND ND
∆8 Tetrahydrocannabinol (Δ8THC) 0.05 / 0.50 N/A ND ND
SUM OF CANNABINOIDS 357.7 mg/g 35.77%
Moisture Test Result

77.8% Tested 02/01/2024 Method: QSP 1224 - Loss on Drying (Moisture)

Learn more

The cannabis plant contains dozens of active compounds called cannabinoids. These compounds are the primary contributors to the psychoactive effects of cannabis.

Cannabinoid testing determines the potency of a sample to aid in dosage considerations.

Pesticide and plant growth regulator analysis utilizing high-performance liquid chromatography-mass spectrometry (HPLC-MS) or gas chromatography-mass spectrometry (GC-MS).

*GC-MS utilized where indicated.

Method: QSP 1212 - Analysis of Pesticides and Mycotoxins by LC-MS or QSP 1213 - Analysis of Pesticides by GC-MS

Pesticide Test Results

02/11/2024

PASS

Swipe left on table to see additional columns

Compound LOD/LOQ
(μg/g)
Action Limit
(μg/g)
Measurement
Uncertainty
(μg/g)
Result
(μg/g)
Result
Abamectin 0.03 / 0.10 0.1 N/A ND Pass
Azoxystrobin 0.02 / 0.07 0.1 N/A ND Pass
Bifenazate 0.01 / 0.04 0.1 N/A ND Pass
Bifenthrin 0.02 / 0.05 3 N/A ND Pass
Boscalid 0.03 / 0.09 0.1 N/A ND Pass
Chlorpyrifos 0.02 / 0.06 ≥ LOD N/A ND Pass
Cypermethrin 0.11 / 0.32 1 N/A ND Pass
Etoxazole 0.02 / 0.06 0.1 N/A ND Pass
Hexythiazox 0.02 / 0.07 0.1 N/A ND Pass
Imidacloprid 0.04 / 0.11 5 N/A ND Pass
Malathion 0.03 / 0.09 0.5 N/A ND Pass
Myclobutanil 0.03 / 0.09 0.1 N/A ND Pass
Permethrin 0.04 / 0.12 0.5 N/A ND Pass
Piperonyl Butoxide 0.02 / 0.07 3 N/A ND Pass
Propiconazole 0.02 / 0.07 0.1 N/A ND Pass
Spiromesifen 0.02 / 0.05 0.1 N/A ND Pass
Tebuconazole 0.02 / 0.07 0.1 N/A ND Pass
Trifloxystrobin 0.03 / 0.08 0.1 N/A ND Pass

Heavy metal analysis utilizing inductively coupled plasma-mass spectrometry (ICP-MS).

Method: QSP 1160 - Analysis of Heavy Metals by ICP-MS

Heavy Metals Test Results

02/12/2024

PASS

Swipe left on table to see additional columns

Compound LOD/LOQ
(μg/g)
Action Limit
(μg/g)
Measurement
Uncertainty
(μg/g)
Result
(μg/g)
Result
Arsenic 0.02 / 0.1 0.2 N/A ND Pass
Cadmium 0.02 / 0.05 0.2 N/A <LOQ Pass
Lead 0.04 / 0.1 0.5 N/A ND Pass
Mercury 0.002 / 0.01 0.1 N/A ND Pass