Sample Name:
NARC-B 2026
Infused, Colorado Infused
Date Issued:
07/10/2024
Sample Information
Cultivator / Manufacturer
Distributor / Tested For
Share
Easily share a link to this results page with your friends, followers, or business partners.
Cannabinoid Analysis - Summary
Total THC: 10.8275 mg/unit
Total CBD: <LOQ
Sum of Cannabinoids: 10.8275 mg/unit
Total Cannabinoids: 10.8275 mg/unit
Density:0.9986 g/mL
Total THC/CBD is calculated using the following formulas to take into account the loss of a carboxyl group during the decarboxylation step:
Total THC = Δ9-THC + (THCa (0.877))
Total CBD = CBD + (CBDa (0.877))
Sum of Cannabinoids = Δ9-THC + THCa + CBD + CBDa + CBG + CBGa + THCV + THCVa + CBC + CBCa + CBDV + CBDVa + Δ8-THC + CBL + CBN
Total Cannabinoids = (Δ9-THC+0.877*THCa) + (CBD+0.877*CBDa) + (CBG+0.877*CBGa) + (THCV+0.877*THCVa) + (CBC+0.877*CBCa) + (CBDV+0.877*CBDVa) + Δ8-THC + CBL + CBN
Sum of Cannabinoids: The concentration of each individual cannabinoid added together as they are, without accounting for decarboxylation. This measurement is of particular importance for certain cannabis products that are not intended to be heated prior to application or consumption.
Total Cannabinoids: The concentration of each acidic cannabinoid, multiplied by 0.877 to account for the loss of molecular mass that happens as it is converted to a neutral cannabinoid when heated. Then this calculated concentration is added to the concentrations of the corresponding neutral cannabinoid already present. This corrected data is of particular importance to both producers and consumers of products intended to be heated prior to application or consumption.
View Complete Test Results:
Cannabinoid Analysis
Tested
Show More
Tested by high-performance liquid chromatography with diode-array detection (HPLC-DAD).
Method: QSP 1157 - Analysis of Cannabinoids by HPLC-DAD
Cannabinoid Test Results
07/08/2024
Result Views
Swipe left on table to see additional columns
Compound |
LOD/LOQ (mg/g) |
Measurement Uncertainty (mg/g) |
Result (mg/g) |
Result (%) |
---|---|---|---|---|
Δ9 Tetrahydrocannabinol (Δ9THC) | 0.0001 / 0.0005 | ±0.00167 | 0.0305 | 0.00305 |
Cannabidiol (CBD) | 0.0001 / 0.0004 | N/A | <LOQ | <LOQ |
Tetrahydrocannabivarin (THCV) | 0.0001 / 0.0005 | N/A | <LOQ | <LOQ |
∆8 Tetrahydrocannabinol (Δ8THC) | 0.0003 / 0.0008 | N/A | <LOQ | <LOQ |
Cannabichromene (CBC) | 0.0001 / 0.0004 | N/A | ND | ND |
Cannabigerol (CBG) | 0.0001 / 0.0002 | N/A | ND | ND |
Cannabicyclol (CBL) | 0.0001 / 0.0004 | N/A | ND | ND |
Cannabinol (CBN) | 0.0001 / 0.0003 | N/A | ND | ND |
Cannabichromenic Acid (CBCa) | 0.0001 / 0.0006 | N/A | ND | ND |
Cannabidivarin (CBDV) | 0.0001 / 0.0005 | N/A | ND | ND |
Cannabidiolic Acid (CBDa) | 0.0001 / 0.0010 | N/A | ND | ND |
Cannabigerolic Acid (CBGa) | 0.0001 / 0.0003 | N/A | ND | ND |
Tetrahydrocannabinolic Acid (THCa) | 0.0001 / 0.0002 | N/A | ND | ND |
Cannabidivarinic Acid (CBDVa) | 0.0001 / 0.0007 | N/A | ND | ND |
Tetrahydrocannabivarinic Acid (THCVa) | 0.0001 / 0.0007 | N/A | ND | ND |
Total THC | ±0.00167 | 0.0305 mg/g | 0.00305% | |
SUM OF CANNABINOIDS | 0.0305 mg/g | 0.00305% |
Unit Mass:
355 grams
Swipe left on table to see additional columns
Δ9-THC per Unit | 10.8275 mg/unit | ||
Total THC per Unit | 10.8275 mg/unit | ||
CBD per Unit | <LOQ | ||
Total CBD per Unit | <LOQ | ||
Sum of Cannabinoids per Unit | 10.8275 mg/unit | ||
Total Cannabinoids per Unit | 10.8275 mg/unit |
Density Test Result
0.9986 g/mL Tested 07/08/2024 Method: QSP 7870 - Sample Preparation
Learn more
The cannabis plant contains dozens of active compounds called cannabinoids. These compounds are the primary contributors to the psychoactive effects of cannabis.
Cannabinoid testing determines the potency of a sample to aid in dosage considerations.
COA ID: 240708M012-002
For quality assurance purposes. Not a Regulatory Hemp Lab Test Report. These results relate only to the sample included on this report. This report shall not be reproduced, except in full, without written approval of the laboratory.
Sample Certification: 6 CCR 1010-21 Colorado Wholesale Food, Industrial Hemp, and Shellfish Regulations; where applicable
Decision Rule: Statements of conformity (e.g. Pass/Fail) to specifications are made in this report without taking measurement uncertainty into account. Where statements of conformity are made in this report, the following decision rules are applied: PASS - Results within limits/specifications, FAIL - Results exceed limits/specifications.
References: limit of detection (LOD), limit of quantification (LOQ), not detected (ND), not tested (NT), μg/g = ppm, μg/kg = ppb
SC Laboratories California LLC. | 100 Pioneer Street, Suite E, Santa Cruz, CA 95060 | (866) 435-0709 | sclabs.com | CDPHE Certified | ISO/IES 17025:2017 PJLA Accreditation Number 87168