Sample Name:
Advanced Nano Tinctures 300mg
Infused, Liquid Edible
Date Issued:
10/06/2025
Sample Information
Cultivator / Manufacturer
Distributor / Tested For
Share
Easily share a link to this results page with your friends, followers, or business partners.
Trace THC Analysis
Tested
Show Less
Tested by high-performance liquid chromatography with diode-array detection (HPLC-DAD).
Method: QSP 1157 - Analysis of Cannabinoids by HPLC-DAD
Trace THC Test Results
10/06/2025
Result Views
Swipe left on table to see additional columns
| Compound |
LOD/LOQ (mg/g) |
Measurement Uncertainty (mg/g) |
Result (mg/g) |
Result (%) |
|---|---|---|---|---|
| Δ9 Tetrahydrocannabinol (Δ9THC) | 0.0006 / 0.0053 | ±0.00058 | 0.0105 | 0.00105 |
| Tetrahydrocannabinolic Acid (THCa) | 0.0003 / 0.0019 | N/A | ND | ND |
| SUM OF CANNABINOIDS | 0.0105 mg/g | 0.00105% |
Density Test Result
0.9992 g/mL Tested 10/06/2025 Method: QSP 7870 - Sample Preparation
Learn more
The cannabis plant contains dozens of active compounds called cannabinoids. These compounds are the primary contributors to the psychoactive effects of cannabis.
Cannabinoid testing determines the potency of a sample to aid in dosage considerations.
COA ID: 251003N037-001
For quality assurance purposes. Not a Regulatory Hemp Lab Test Report. These results relate only to the sample included on this report. This report shall not be reproduced, except in full, without written approval of the laboratory.
Sample Certification: California Code of Regulations Title 4 Division 19. Department of Cannabis Control Business and Professions Code. Reference: Sections 26100, 26104 and 26110, Business and Professions Code.
Decision Rule: Statements of conformity (e.g. Pass/Fail) to specifications are made in this report without taking measurement uncertainty into account. Where statements of conformity are made in this report, the following decision rules are applied: PASS - Results within limits/specifications, FAIL - Results exceed limits/specifications.
References: limit of detection (LOD), limit of quantification (LOQ), not detected (ND), not tested (NT), μg/g = ppm, μg/kg = ppb
SC Laboratories California LLC. | 100 Pioneer Street, Suite E, Santa Cruz, CA 95060 | (866) 435-0709 | sclabs.com | C8-0000013-LIC | ISO/IES 17025:2017 PJLA Accreditation Number 87168