Sample Name:
CBD Vape Juice - Grape Candy - 1000mg
Infused, Liquid Edible
Date Issued:
11/18/2024
Sample Information
Cultivator / Manufacturer
Distributor / Tested For
Share
Easily share a link to this results page with your friends, followers, or business partners.
Cannabinoid Analysis - Summary
Total THC: Not Detected
Total CBD: 1005.900 mg/unit
Sum of Cannabinoids: 1017.780 mg/unit
Total Cannabinoids: 1017.780 mg/unit
Density:1.1039 g/mL
Total THC/CBD is calculated using the following formulas to take into account the loss of a carboxyl group during the decarboxylation step:
Total THC = Δ9-THC + (THCa (0.877))
Total CBD = CBD + (CBDa (0.877))
Sum of Cannabinoids = Δ9-THC + THCa + CBD + CBDa + CBG + CBGa + THCV + THCVa + CBC + CBCa + CBDV + CBDVa + Δ8-THC + CBL + CBN
Total Cannabinoids = (Δ9-THC+0.877*THCa) + (CBD+0.877*CBDa) + (CBG+0.877*CBGa) + (THCV+0.877*THCVa) + (CBC+0.877*CBCa) + (CBDV+0.877*CBDVa) + Δ8-THC + CBL + CBN
Sum of Cannabinoids: The concentration of each individual cannabinoid added together as they are, without accounting for decarboxylation. This measurement is of particular importance for certain cannabis products that are not intended to be heated prior to application or consumption.
Total Cannabinoids: The concentration of each acidic cannabinoid, multiplied by 0.877 to account for the loss of molecular mass that happens as it is converted to a neutral cannabinoid when heated. Then this calculated concentration is added to the concentrations of the corresponding neutral cannabinoid already present. This corrected data is of particular importance to both producers and consumers of products intended to be heated prior to application or consumption.
Safety Analysis - Summary
Δ9-THC per Unit: Pass
View Complete Test Results:
Cannabinoid Analysis
Tested
Show More
Tested by high-performance liquid chromatography with diode-array detection (HPLC-DAD).
Method: QSP 1157 - Analysis of Cannabinoids by HPLC-DAD
Cannabinoid Test Results
11/18/2024
Result Views
Swipe left on table to see additional columns
Compound |
LOD/LOQ (mg/mL) |
Measurement Uncertainty (mg/mL) |
Result (mg/mL) |
Result (%) |
---|---|---|---|---|
Cannabidiol (CBD) | 0.004 / 0.011 | ±1.2507 | 33.530 | 3.0374 |
Cannabidivarin (CBDV) | 0.002 / 0.012 | ±0.0162 | 0.396 | 0.0359 |
Cannabichromene (CBC) | 0.003 / 0.010 | N/A | ND | ND |
Cannabigerol (CBG) | 0.002 / 0.006 | N/A | ND | ND |
Cannabicyclol (CBL) | 0.003 / 0.010 | N/A | ND | ND |
Cannabinol (CBN) | 0.001 / 0.007 | N/A | ND | ND |
Cannabichromenic Acid (CBCa) | 0.001 / 0.015 | N/A | ND | ND |
Cannabidiolic Acid (CBDa) | 0.001 / 0.026 | N/A | ND | ND |
Cannabigerolic Acid (CBGa) | 0.002 / 0.007 | N/A | ND | ND |
Tetrahydrocannabivarin (THCV) | 0.002 / 0.012 | N/A | ND | ND |
Tetrahydrocannabinolic Acid (THCa) | 0.001 / 0.005 | N/A | ND | ND |
Cannabidivarinic Acid (CBDVa) | 0.001 / 0.018 | N/A | ND | ND |
Tetrahydrocannabivarinic Acid (THCVa) | 0.002 / 0.019 | N/A | ND | ND |
∆8 Tetrahydrocannabinol (Δ8THC) | 0.01 / 0.02 | N/A | ND | ND |
Δ9 Tetrahydrocannabinol (Δ9THC) | 0.002 / 0.014 | N/A | ND | ND |
SUM OF CANNABINOIDS | 33.926 mg/mL | 3.0733% |
Unit Mass:
30 milliliters
Swipe left on table to see additional columns
Δ9-THC per Unit | 110 per-package limit | ND | Pass |
Total THC per Unit | ND | ||
CBD per Unit | 1005.900 mg/unit | ||
Total CBD per Unit | 1005.900 mg/unit | ||
Sum of Cannabinoids per Unit | 1017.780 mg/unit | ||
Total Cannabinoids per Unit | 1017.780 mg/unit |
Density Test Result
1.1039 g/mL Tested 11/18/2024 Method: QSP 7870 - Sample Preparation
Learn more
The cannabis plant contains dozens of active compounds called cannabinoids. These compounds are the primary contributors to the psychoactive effects of cannabis.
Cannabinoid testing determines the potency of a sample to aid in dosage considerations.
COA ID: 241115K048-001
For quality assurance purposes. Not a Regulatory Hemp Lab Test Report. These results relate only to the sample included on this report. This report shall not be reproduced, except in full, without written approval of the laboratory.
Sample Certification: California Code of Regulations Title 4 Division 19. Department of Cannabis Control Business and Professions Code. Reference: Sections 26100, 26104 and 26110, Business and Professions Code.
Decision Rule: Statements of conformity (e.g. Pass/Fail) to specifications are made in this report without taking measurement uncertainty into account. Where statements of conformity are made in this report, the following decision rules are applied: PASS - Results within limits/specifications, FAIL - Results exceed limits/specifications.
References: limit of detection (LOD), limit of quantification (LOQ), not detected (ND), not tested (NT)
SC Laboratories California LLC. | 100 Pioneer Street, Suite E, Santa Cruz, CA 95060 | (866) 435-0709 | sclabs.com | C8-0000013-LIC | ISO/IES 17025:2017 PJLA Accreditation Number 87168