Certificate of Analysis
HEMP QUALITY ASSURANCE TEST

Sample Name:

Eir Health Oil No.30

Infused, Non-Inhalable

Date Issued:

06/11/2021

Serving Size:

1 milliliters

Total THC 61.770 mg/unit
Total CBD 4612.920 mg/unit
Sum Cannabinoids 4923.540 mg/unit
Total Cannabinoids 4848.930 mg/unit

Sample Information

Sample Details

Sample ID:210608R032

Batch Number:6100521

Cultivator / Manufacturer

Show Details

Distributor / Tested For

Show Details

Share

Easily share a link to this results page with your friends, followers, or business partners.

Cannabinoid Analysis - Summary

Total THC: 61.770 mg/unit

Total CBD: 4612.920 mg/unit

Sum of Cannabinoids: 4923.540 mg/unit

Total Cannabinoids: 4848.930 mg/unit

Density:0.9578 g/mL

Total THC/CBD is calculated using the following formulas to take into account the loss of a carboxyl group during the decarboxylation step:
Total THC = Δ9-THC + (THCa (0.877))
Total CBD = CBD + (CBDa (0.877))

Sum of Cannabinoids = Δ9-THC + THCa + CBD + CBDa + CBG + CBGa + THCV + THCVa + CBC + CBCa + CBDV + CBDVa + Δ8-THC + CBL + CBN

Total Cannabinoids = (Δ9-THC+0.877*THCa) + (CBD+0.877*CBDa) + (CBG+0.877*CBGa) + (THCV+0.877*THCVa) + (CBC+0.877*CBCa) + (CBDV+0.877*CBDVa) + Δ8-THC + CBL + CBN

Sum of Cannabinoids: The concentration of each individual cannabinoid added together as they are, without accounting for decarboxylation. This measurement is of particular importance for certain cannabis products that are not intended to be heated prior to application or consumption.

Total Cannabinoids: The concentration of each acidic cannabinoid, multiplied by 0.877 to account for the loss of molecular mass that happens as it is converted to a neutral cannabinoid when heated. Then this calculated concentration is added to the concentrations of the corresponding neutral cannabinoid already present. This corrected data is of particular importance to both producers and consumers of products intended to be heated prior to application or consumption.

Safety Analysis - Summary

Δ9-THC per Unit: Pass

Pesticides: Pass

Heavy Metals: Pass

View Complete Test Results:

Tested by high-performance liquid chromatography with diode-array detection (HPLC-DAD).

Method: QSP 1157 - Analysis of Cannabinoids by HPLC-DAD

Summary

Total THC: 61.770 mg/unit

9-THC+0.877*THCa)

Total CBD: 4612.920 mg/unit

(CBD+0.877*CBDa)

Total Cannabinoids: 4848.930 mg/unit

Total CBG: 37.980 mg/unit

Total CBG (CBG+0.877*CBGa)

Total THCV: 1.500 mg/unit

Total THCV (THCV+0.877*THCVa)

Total CBC: 52.650 mg/unit

Total CBC (CBC+0.877*CBCa)

Total CBDV: 74.700 mg/unit

Total CBDV (CBDV+0.877*CBDVa)

Learn more

The cannabis plant contains dozens of active compounds called cannabinoids. These compounds are the primary contributors to the psychoactive effects of cannabis.

Cannabinoid testing determines the potency of a sample to aid in dosage considerations.

Cannabinoid Test Results

06/10/2021

Result Views

Swipe left on table to see additional columns

Compound LOD/LOQ
(mg/mL)
Measurement
Uncertainty
(mg/mL)
Result
(mg/mL)
Result
(%)
Cannabidiol (CBD) 0.004 / 0.011 ±6.5622 136.998 14.3034
Cannabidiolic Acid (CBDa) 0.001 / 0.026 ±0.6978 19.117 1.9959
Cannabidivarin (CBDV) 0.002 / 0.012 ±0.1200 2.291 0.2392
Δ9 Tetrahydrocannabinol (Δ9THC) 0.002 / 0.014 ±0.1172 1.662 0.1735
Cannabichromene (CBC) 0.003 / 0.010 ±0.0633 1.529 0.1596
Cannabigerol (CBG) 0.002 / 0.006 ±0.0700 1.126 0.1176
Tetrahydrocannabinolic Acid (THCa) 0.001 / 0.005 ±0.0103 0.453 0.0473
Cannabichromenic Acid (CBCa) 0.001 / 0.015 ±0.0126 0.258 0.0269
Cannabidivarinic Acid (CBDVa) 0.001 / 0.018 ±0.0027 0.227 0.0237
Cannabigerolic Acid (CBGa) 0.002 / 0.007 ±0.0047 0.160 0.0167
Cannabinol (CBN) 0.001 / 0.007 ±0.0052 0.142 0.0148
Cannabicyclol (CBL) 0.003 / 0.010 ±0.0050 0.105 0.0110
Tetrahydrocannabivarin (THCV) 0.002 / 0.012 ±0.0032 0.050 0.0052
Tetrahydrocannabivarinic Acid (THCVa) 0.002 / 0.019 N/A ND ND
∆8 Tetrahydrocannabinol (Δ8THC) 0.01 / 0.02 N/A ND ND
SUM OF CANNABINOIDS 164.118 mg/mL 17.1349%
Unit Mass:

30 milliliters

/

Serving Size:

1 milliliters

Swipe left on table to see additional columns

Δ9-THC per Unit 1120 per-package limit 49.860 mg/unit Pass
Δ9-THC per Serving 1.662 mg/serving
Total THC per Unit 61.770 mg/unit
Total THC Per Serving 2.059 mg/serving
CBD per Unit 4109.940 mg/unit
CBD per Serving 136.998 mg/serving
Total CBD per Unit 4612.920 mg/unit
Total CBD per Serving 153.764 mg/serving
Sum of Cannabinoids per Unit 4923.540 mg/unit
Sum of Cannabinoids per Serving 164.118 mg/serving
Total Cannabinoids per Unit 4848.930 mg/unit
Total Cannabinoids per Serving 161.631 mg/serving
Density Test Result

0.9578 g/mL Tested 06/10/2021 Method: QSP 7870 - Sample Preparation

Learn more

The cannabis plant contains dozens of active compounds called cannabinoids. These compounds are the primary contributors to the psychoactive effects of cannabis.

Cannabinoid testing determines the potency of a sample to aid in dosage considerations.

Pesticide and plant growth regulator analysis utilizing high-performance liquid chromatography-mass spectrometry (HPLC-MS) or gas chromatography-mass spectrometry (GC-MS).

*GC-MS utilized where indicated.

Method: QSP 1212 - Analysis of Pesticides and Mycotoxins by LC-MS or QSP 1213 - Analysis of Pesticides by GC-MS

Pesticide Test Results

06/09/2021

PASS

Swipe left on table to see additional columns

Compound LOD/LOQ
(μg/g)
Action Limit
(μg/g)
Measurement
Uncertainty
(μg/g)
Result
(μg/g)
Result
Abamectin 0.03 / 0.10 0.3 N/A ND Pass
Azoxystrobin 0.01 / 0.04 40 N/A ND Pass
Bifenazate 0.01 / 0.02 5 N/A ND Pass
Bifenthrin 0.01 / 0.02 0.5 N/A ND Pass
Boscalid 0.02 / 0.06 10 N/A ND Pass
Chlorpyrifos 0.02 / 0.06 ≥ LOD N/A ND Pass
Cypermethrin 0.1 / 0.3 1 N/A ND Pass
Etoxazole 0.010 / 0.028 1.5 N/A ND Pass
Hexythiazox 0.01 / 0.04 2 N/A ND Pass
Imidacloprid 0.01 / 0.04 3 N/A ND Pass
Malathion 0.02 / 0.05 5 N/A ND Pass
Myclobutanil 0.03 / 0.1 9 N/A ND Pass
Permethrin 0.03 / 0.09 20 N/A ND Pass
Piperonyl Butoxide 0.003 / 0.009 8 N/A ND Pass
Propiconazole 0.01 / 0.03 20 N/A ND Pass
Spiromesifen 0.02 / 0.05 12 N/A ND Pass
Tebuconazole 0.02 / 0.07 2 N/A ND Pass
Trifloxystrobin 0.01 / 0.03 30 N/A ND Pass

Heavy metal analysis utilizing inductively coupled plasma-mass spectrometry (ICP-MS).

Method: QSP 1160 - Analysis of Heavy Metals by ICP-MS

Heavy Metals Test Results

06/10/2021

PASS

Swipe left on table to see additional columns

Compound LOD/LOQ
(μg/g)
Action Limit
(μg/g)
Measurement
Uncertainty
(μg/g)
Result
(μg/g)
Result
Arsenic 0.02 / 0.1 1.5 N/A ND Pass
Cadmium 0.02 / 0.05 0.5 N/A ND Pass
Lead 0.04 / 0.1 0.5 N/A ND Pass
Mercury 0.002 / 0.01 3 N/A ND Pass

Your current browser is unsupported. Please install latest version of Firefox, Chrome or IE to view this site.